Key specifications
- Differential inputs
- 12, 14, 16 bit resolution, 0.3 % DC accuracy
- Up to 50 MSa/s sampling, 50 MHz bandwidth
- 128 kpoints memory per channel
The Automotive Test Scope ATS5004DW is a 4 channel automotive WiFi oscilloscope with differential inputs. Besides the normal features of a professional USB oscilloscope, the Automotive Test Scope ATS5004D has some specific features like SureConnect connection test and resistance measurement that make it an ideal instrument for automotive measurements.
![]() |
![]() |
![]() |
![]() |
![]() |
Specifications
Acquisition system | |||||
---|---|---|---|---|---|
Number of input channels | 4 analog | ||||
Ch1, Ch2, Ch3, Ch4 | Isolated female BNC | ||||
Type | Differential | ||||
Resolution | User selectable in software | ||||
Native | 12 bit | ||||
Enhanced | 14, 16 bit | ||||
Accuracy | 0.3 % of full scale ± 1 LSB | ||||
Ranges (Full scale) | ±200 mV ±400 mV ±800 mV | ±2 V ±4 V ±8 V | ±20 V ±40 V ±80 V | ||
Coupling | AC/DC | ||||
Impedance | 2 MΩ / 40 pF | ||||
Noise (in 200 mV range) | 135 µVrms | ||||
Maximum input voltage (in all ranges) | ±200 V (DC + AC peak < 10 kHz) with 1:10 attenuator ±300 V (DC + AC peak < 10 kHz) | ||||
Maximum Common Mode voltage | 200 mV to 800 mV ranges : 2 V 2 V to 8 V ranges : 20 V 20 V to 80 V ranges : 200 V | ||||
Common Mode Rejection Ratio | -48 dB | ||||
Bandwidth (-3dB) | DC to 50 MHz maximum | ||||
AC coupling cut off frequency (-3dB) | 1 Hz | ||||
Channel Isolation | 500 V | ||||
Channel Separation | -80 dB | ||||
SureConnect | |||||
Maximum voltage on connection | 200 V (DC + AC peak < 10 kHz) | ||||
Resistance measurement | |||||
Ranges (Full scale) | 100 Ω 200 Ω 500 Ω | 1 kΩ 2 kΩ 5 kΩ | 10 kΩ 20 kΩ 50 kΩ | 100 kΩ 200 kΩ 500 kΩ | 1 MΩ 2 MΩ |
Accuracy | 3% | ||||
Response time (to 95%) | < 5 ms | ||||
Maximum sampling (on all channels simultaneously) | 12 bit | 14 bit | 16 bit | ||
Scope mode (block) | 50 MSa/s | 3.125 MSa/s | 195.3 kSa/s | ||
Streaming mode | 500 kSa/s | 480.8 kSa/s | 195.3 kSa/s | ||
Sampling clock source | |||||
Internal | Quartz | ||||
Accuracy | ±0.01 % | ||||
Stability | ±100 ppm over -40 °C to +85 °C | ||||
Time base aging | ±5 ppm/year | ||||
External | On extension connector | ||||
Voltage | 3.3 V TTL, 5 V TTL tolerant | ||||
Frequency range | 95 MHz to 105 MHz | ||||
Memory | 128 KSamples per channel | ||||
Trigger | Only available in scope/block mode, not in streaming mode | ||||
System | Digital, 2 levels | ||||
Source | CH1, CH2, CH3, CH4, OR, digital external | ||||
Trigger modes | Rising edge, Falling edge Inside window, Outside window | ||||
Level adjustment | 0 to 100 % of full scale | ||||
Hysteresis adjustment | 0 to 100 % of full scale | ||||
Resolution | 0.025 % (12 bits) | ||||
Pre trigger | 0 to 131071 samples, 1 sample resolution | ||||
Post trigger | 0 to 131071 samples, 1 sample resolution | ||||
Trigger hold-off | 0 to 1048576 Samples, 1 sample resolution | ||||
Digital external trigger | |||||
Input | Extension connector | ||||
Range | 0 to 3.3 V (5 V max) | ||||
Coupling | DC | ||||
Interface | |||||
Interface | |||||
USB | 2.0 High Speed (480 Mbit/s) | ||||
Network | 1 Gbps | ||||
WiFi | 802.11 | ||||
Power Requirements | |||||
Power | From USB, external input or built-in battery | ||||
Consumption | 12 VDC 2 A max | ||||
External power | From power adapter | ||||
Internal battery | Li-ion | ||||
Capacity | 7000 mAh, 3.7 V | ||||
Weight | 160 g | ||||
Physical | |||||
Instrument | |||||
Height | 44 mm (1.7 inch) | ||||
Length | 187 mm (6.7 inch) | ||||
Width | 215 mm (5.2 inch) | ||||
Weight | 791 g (27.9 ounce) | ||||
I/O connectors | |||||
Channel 1...4 | Isolated BNC, female | ||||
LAN | RJ45 socket | ||||
USB | USB 3.0 type B Super Speed socket | ||||
Extension connector | D-sub 25 pins female | ||||
Power | 3.5 mm power socket | ||||
System Requirements | |||||
PC I/O connection | USB 2.0, USB 3.0 or USB 3.1 RJ45 WiFi | ||||
Operating System | Windows 10 / 11, 64 bits Linux (via own software using the libtiepie-hw SDK) | ||||
Operating Environment | |||||
Operating | |||||
Ambient temperature | 20°C to 25°C for rated accuracy (10°C to 40°C without specifications) | ||||
Relative humidity | 10 % to 90 %, non condensing | ||||
Charging | |||||
Ambient temperature | 0°C to 35°C | ||||
Relative humidity | 10 % to 90 %, non condensing | ||||
Storage | |||||
Ambient temperature | 0°C to 35°C | ||||
Relative humidity | 5 % to 95 %, non condensing | ||||
Certifications and Compliances | |||||
CE mark compliance | Yes | ||||
RoHS | Yes | ||||
EN 55011:2009/A1:2010 | Yes | ||||
EN 55022:2006/A1:2007 | Yes | ||||
EN 61000-6-1:2007 | Yes | ||||
EN 61000-6-3:2007 | Yes | ||||
Package | |||||
Convenient carrying case | Carry case BB453 | ||||
Instrument | Automotive Test Scope ATS5004DW | ||||
Measure leads | 4 x Measure lead TP-C1812B, BNC -> 4 mm banana plug | ||||
Differential attenuator | 4 x Differential attenuator TP-DA10 | ||||
Accessories | Ground compensation Cable TP-GCC150 Handyscope / WiFiScope power supply USB3 cable, 1.5 m long network cable, 3 m long | ||||
Software | Windows 10 / 11, 64 bits, via website | ||||
Drivers | Windows 10 / 11, 64 bits, via website | ||||
Manual | instrument manual and software user's manuals color printed and digital, via website | ||||
Total package weight | Approx. 3 kg | ||||
Customer service | |||||
TiePie engineering instruments are designed, manufactured and tested to provide high reliability. In the unlikely event you experience difficulties, the TiePie engineering instruments are fully warranted for two years. | |||||
This warranty includes | All parts and labor (excluding probes and/or measure leads and/or batteries) Warranty on batteries is 6 months. No charge for return shipping Long-term 7 year support Upgrade to the latest software at no charge |