Home Page
Home|Sitemap|Contact
Singapore - 
	DT TECHSOLUTIONS PTE LTD   India - DT TECHSOLUTIONS PVT LTD
Home Page
Your Cart
Your shopping cart is empty!

Currency
American Dollar

Automotive Test Scope ATS610004DW-XMSG

Printer Friendly Tell a Friend
Automotive Test Scope ATS610004DW-XMSG
Price: USD3,022.80

Qty:

Highlights:
  • WiFi / LAN / USB connected
  • 14 bit (0.006 %) resolution (16 bit enhanced resolution)
  • Up to 1 GSa/s sampling

  Description  

Automotive Test Scope ATS610004DW-XMSG

Product Details

Key specifications

  • WiFi / LAN / USB connected
  • 14 bit (0.006 %) resolution (16 bit enhanced resolution)
  • Up to 1 GSa/s sampling
  • 250 MHz bandwidth
  • Up to 200 MSa/s continuous streaming
  • Up to 256 Mpoints memory per channel
  • 0.25 % DC vertical accuracy, 0.1 % typical
  • 1 ppm time base accuracy

This powerful automotive WiFi oscilloscope combines fast sampling up to 1 GSa/s with high resolutions of 12, 14 and 16 bit and a large memory of 64 Mpoints per channel with four differential channels. Additionally, the automotive WiFi oscilloscope supports continuous streaming measurements up to 200 MSa/s.

The Automotive Test Scope ATS610004DW-XMSG is delivered with SureConnect connection test and resistance measurement on each channel.

Also, the Automotive Test Scope ATS610004DW-XMSG is delivered with SafeGround. With SafeGround you can switch the differential inputs of the Automotive Test Scope ATS610004DW-XMSG into single ended inputs with ground protection. It allows to make measurements using standard attenuating probes or standard shielded measure leads and protects the scope when a short circuit to ground is created.

Specifications

Acquisition system

Number of input channels4 analog
CH1, CH2, CH3, CH4Isolated female BNC
TypeDifferential input
ResolutionUser selectable in software
Native8, 12, 14 bit
Enhanced16 bit
DC Accuracy0.25 % (0.1 % typical) of full scale ± 1 LSB at 20°C to 25°C
To achieve rated accuracy, allow the instrument to settle for 20 minutes. When subjected to extreme temperatures, allow additional time for internal temperatures to stabilize.
Ranges (full scale)±200 mV
±400 mV
±800 mV
±2 V
±4 V
±8 V
±20 V
±40 V
±80 V
CouplingAC/DC
Impedance2 MOhm / 12 pF ± 1 %
1 MOhm / 20 pF ± 1 % when SafeGround enabled
Noise (in 200 mV range)300 µVrms
Maximum voltage200 V (DC + AC peak < 10 kHz)
Maximum Common Mode voltage200 mV to 800 mV ranges : 2 V
2 V to 8 V ranges : 20 V
20 V to 80 V ranges : 200 V
Common Mode Rejection Ratio-47 dB
Bandwidth 
-3dB at 75 % of full scale input250 MHz
Limit, selectable per channelOff (250 MHz), 150 MHz, 100 MHz, 50 MHz
AC coupling cut off frequency (-3dB)±1.5 Hz
SureConnect 
Maximum voltage on connection200 V (DC + AC peak < 10 kHz)
Resistance measurement 
Ranges (Full scale)1 kΩ
2 kΩ
5 kΩ
10 kΩ
20 kΩ
50 kΩ
100 kΩ
200 kΩ
500 kΩ
1 MΩ
2 MΩ
Accuracy1 % of full scale
Response time (to 95%)< 10 µs
SafeGround 
Maximum voltage on connection200 V (DC + AC peak < 10 kHz)
Maximum switch off current500 mA
Response time< 100 ns
 
Maximum sampling rate8 bit12 bit14 bit16 bit
measuring one channel1 GSa/s500 MSa/s100 MSa/s6.25 MSa/s
measuring two channels500 MSa/s200 MSa/s100 MSa/s6.25 MSa/s
measuring three or four channels200 MSa/s100 MSa/s100 MSa/s6.25 MSa/s
 
Maximum streaming rate 18 bit12 bit14 bit16 bit
8 bit 
measuring one channel200 MSa/s 2100 MSa/s 3100 MSa/s 36.25 MSa/s 6
measuring two channels100 MSa/s 350 MSa/s 450 MSa/s 46.25 MSa/s 6
measuring three or four channels50 MSa/s 425 MSa/s 525 MSa/s 56.25 MSa/s 6
  1. Due to computer restrictions, on some computers the highest streaming rates may not be available.
    When LAN/WiFi connected, the maximum streaming rate is limited, and depends on the quality of the network.
  2. ≤ 40 MSs/s when connected to USB 2.0 or via LAN/WiFi
  3. ≤ 20 MSs/s when connected to USB 2.0 or via LAN/WiFi
  4. ≤ 10 MSs/s when connected to USB 2.0 or via LAN/WiFi
  5. ≤ 5 MSs/s when connected to USB 2.0 or via LAN/WiFi
  6. ≤ 3.125 MSs/s when connected to USB 2.0 or via LAN/WiFi
Sampling clock source 
InternalTCXO
Accuracy± 0.0001 %
Stability± 1 ppm over 0°C to 55°C
Time base aging±1 ppm/year
ExternalLVDS, on CMI connectors
Input frequency10 MHz ± 1 %
16.369 MHz ± 1 %
Memoryvia USBvia WiFi/LAN
8 bit resolution 
Measuring one channel256 MSa per channel64 MSa per channel
Measuring two channels128 MSa per channel32 MSa per channel
Measuring three or four channels64 MSa per channel16 MSa per channel
12, 14, 16 bit resolution 
Measuring one channel128 MSa per channel32 MSa per channel
Measuring two channels64 MSa per channel16 MSa per channel
Measuring three or four channels32 MSa per channel8 MSa per channel
 
Trigger Only available in scope/block mode, not in streaming mode
SystemDigital, 2 levels
SourceCH1, CH2, CH3, CH4, OR, digital external
Trigger modesRising edge, Falling edge, Any edge
Inside window, Outside window, Enter window, Exit window (time conditions only on Ch1)
Pulse width (only on Ch1)
Interval (only on Ch1)
Level adjustment0 to 100 % of full scale
Hysteresis adjustment0 to 100 % of full scale
Resolution0.006 % (14, 16 bits) / 0.025% (12 bits)
Pre trigger0 to selected record length, 1 sample resolution
Post trigger0 to selected record length, 1 sample resolution
Trigger hold-off0 to 63 MSamples, 1 sample resolution
Trigger delay0 to 8 GSamples, 1 sample resolution
Digital external trigger 
InputExtension connector pins 1 and 2
Range0 to 2.5 V (TTL)
CouplingDC
Jitter≤ 1 sample

Multi-instrument synchronization

Using CMISynchronizing instruments via CMI is available when all instruments are connected via USB.
Maximum number of instrumentsLimited by number of available USB ports
Synchronization accuracy0 ppm
CMI interface2x, CMI 1, CMI 2
Required coupling cableTP-C50H Coupling cable CMI
Maximum coupling cable length50 cm
Using WCMISynchronizing instruments via WCMI is available when instruments are connected via USB, LAN and WiFi.
Maximum number of instrumentsNo limitation
Required coupling moduleWCMI - 8, WCMI - 9
Clock synchronization accuracy≤ 1 ppm, typical ≤ 0.2 ppm
Trigger jitter at sample rate 1≤ 1 MSa/s> 1 MSa/s
2 x "5"≤ ±2 samples≤ ±2 µs
"5" and "6" 
Trigger source "5"≤ ±2 samples≤ ±2 µs
Trigger source "6"≤ ±8 samples≤ ±8 µs
2 x "6"≤ ±8 samples≤ ±8 µs
  1. "5" = WiFiScope WS5 or Handyscope HS5.
    "6" = WiFiScope WS6 DIFF, WiFiScope WS6, Handyscope HS6 DIFF, Handyscope HS6, ATS610004DW-XMSG, ATS610004D-XMSG, ATS605004DW-XMS or ATS605004D-XMS

Probe calibration

OutputExtension connector pins 3 (signal) and 6 (ground)
SignalSquare wave
Level-1 V to 1 V
Frequency1 kHz

Interface

Interface 
USBUSB 3.0 SuperSpeed (5 Gbit/s);
(USB 2.0 HighSpeed compatible)
Network1 Gbps
WiFi802.11

Power Requirements

PowerFrom USB, external input or built-in battery
Consumption12 VDC 2 A max
External powerFrom power adapter
Internal batteryLi-ion
Capacity7000 mAh, 3.7 V
Weight160 g

Physical

Instrument
Height44 mm (1.7 inch)
Length187 mm (6.7 inch)
Width215 mm (5.2 inch)
Weight791 g (27.9 ounce)
USB cord length1.5 m (59 inch)

I/O connectors

Channel 1, 2, 3, 4Isolated BNC, female
LANRJ45 socket
USBUSB 3.0 type B Super Speed socket
Extension connectorD-sub 9 pins female
Power3.5 mm power socket
CMI connectors2 x HDMI type C socket

System requirements

PC I/O connectionUSB 2.0, USB 3.0 or USB 3.1
RJ45
WiFi
Operating systemWindows 10 / 11, 64 bits
Linux (via own software using the libtiepie-hw SDK)

Environmental conditions

Operating 
Ambient temperature20°C to 25°C for rated accuracy (10°C to 40°C without specifications)
Relative humidity10 % to 90 %, non condensing
Charging 
Ambient temperature0°C to 35°C
Relative humidity10 % to 90 %, non condensing
Storage 
Ambient temperature0°C to 35°C
Relative humidity5 % to 95 %, non condensing

Certifications and Compliances

CE mark complianceYes
RoHSYes
EN 55011:2009/A1:2010Yes
EN 55022:2006/A1:2007Yes
EN 61000-6-1:2007Yes
EN 61000-6-3:2007Yes

Package contents

Carry caseCarry case BB453
InstrumentAutomotive Test Scope ATS610004DW-XMSG
Measure leads4 x Measure lead TP-C1812B, Differential BNC -> 4 mm banana plug
Differential attenuator4 x Differential attenuator TP-DA10
Alligator clips, largeAlligator Clip TP-AC80I - Set of 8: Green, Blue, Yellow, Red, 4 Black, 8 large alligator clips
Alligator clips, mediumAlligator Clip TP-AC10I - Set of 8: Green, Blue, Yellow, Red, 4 Black, 8 medium alligator clips
Alligator clips, smallAlligator Clip TP-AC5 - Set of 8: Green, Blue, Yellow, Red, 4 Black, 8 small alligator clips
AccessoriesGround compensation Cable TP-GCC150
Handyscope / WiFiScope power supply
USB3 cable, 1.5 m long
network cable, 3 m long
Probe compensation cable TP-DB9-BNC-30
Softwarefor Windows 10 / 11, 64 bits, via website
Driversfor Windows 10 / 11, 64 bits, via website
Manualsinstrument manual and software user's manuals
color printed and digital, via website

Optional Accessories

Optional accessories for the Automotive Test Scope ATS610004DW-XMSG need to be ordered separately
Oscilloscope probeOscilloscope Probe 1:1-1:10 - HP-3250I
Measure lead single endedMeasure lead TP-BNCI-100

Customer service

TiePie engineering instruments are designed, manufactured and tested to provide high reliability. In the unlikely event you experience difficulties, the TiePie engineering instruments are fully warranted for two years.
This warranty includesAll parts and labor (excluding probes and/or measure leads and/or batteries)
Warranty on batteries is 6 months.
No charge for return shipping
Long-term 7 year support
Upgrade to the latest software at no charge

 User Manual

© 2013 DT TECHSOLUTIONS PTE LTD