Units
Unit |
Voltage range |
Current range |
SM 15-400 |
0 - 15 V |
0 - 400 A |
SM 30-200 |
0 - 30 V |
0 - 200 A |
SM 45-140 |
0 - 45 V |
0 - 140 A |
SM 60-100 |
0 - 60 V |
0 - 100 A |
SM 70-90 |
0 - 70 V |
0 - 90 A |
SM 120-50 |
0 - 120 V |
0 - 50 A |
SM 300-20 |
0 - 300 V |
0 - 20 A |
SM 600-10 |
0 - 600 V |
0 - 10 A |
Features:
- Designed for long life at full power
- Excellent dynamic response to load changes
- Protected against all overload and short circuit conditions
- EMC surpasses CE requirements: low emission und high immunity
- Low audible noise: fans are temperature controlled
Functionalities:
- Master / Slave parallel and series operation with voltage and current sharing
- Stacking is allowed, space between units is not required
- High power system configuration from multiple units
- 19” rack mounting or laboratory use (feet included)
- Remote sensing
- Interlock
Options
-
High Speed Programming
A 10 to 20 times higher programming speed and lower output capacitance. Excellent for laser applications, fast test systems or as current source with low parallel capacitance as used in plasma chambers. For more information download the data sheet High Speed Programming.
-
Digital Voltage and Current Setting
Reliable, long life digital encoders are implemented at the front panel. Includes total front panel lock and a coarse or fine pitch adjustment depending on the turning speed. Standard feauture on SM300-20 and SM600-10. For more information download the data sheet Digital Encoders.
-
Sequencer
Arbitrary Waveform generator or standalone automation. The sequencer is integrated in the Ethernet controller. For more information download the data sheet Ethernet Interface.
-
Increased Output Power
For conservatively rated units extra output power (with the same reliability) is allowed. At some derating, either the maximum output voltage or current of these units can be increased by about 10%. Contact us or our local distributor for information which units extra output power is allowed.
|
-
2-Quadrant Output: Power Sink
The 2-quadrant operation maintains the output voltage constant regardless the output power is positive or negative (for units up to max. 70 V only). Ideal for PWM-speed controlled DC-motors and ATE-systems. For more information download the data sheet Power Sink.
-
Secured Voltage and Current Setting
For maximum security the settings for CC and CV can be adjusted with a screwdriver only and are protected with a plastic cap from accidental adjusting. SM300-20, SM600-10 and units with digital voltage and current setting already have secured settings.
-
Software Control and Interfaces
Factory installed programming interfaces*:
- Ethernet (incl. sequencer)
- ISO AMP CARD - isolated analog
External interface modules:
* there is room for only one of the interfaces in a unit
|
Data sheet
Product manual