J2102B Common Mode Transformer

Printer Friendly Tell a Friend
J2102B Common Mode Transformer
Price: 

Model:
Qty:

Highlights:
  • Greatly attenuates the effects of low frequency ground loops
  • Supports the 2 Port Shunt Thru impedance measurement required for Power Distribution Networks (PDN’s)

  Description  

J2102B Common Mode Transformer

Product Details

What's included
J2102B Common Mode Transformer - BNC or N Type Connector
 User manual
1 Year Warranty
2-Port Shunt-Through Measurement using the J2102B and the Bode 100 VNA

2-Port Shunt-Through Measurement using the J2102B and the Copper Mountain S5065

Model Description
J2102B-BNC J2102B Common Mode Transformer – BNC Connectors
J2102B-N J2102B Common Mode Transformer – N Connectors

The simplest and most effective method for eliminating a ground loop is to add a wideband common mode transformer to the measurement, such as the Picotest J2102B Common Mode Transformer. The transformer for a low impedance PDN measurement must have very wide bandwidth, low loss and tight coupling, otherwise, the results will not be accurate over the measured frequency range. It is also important to maintain the 50 Ohm transmission line impedance through this transformer. The J2102B accomplishes this with ease.

Features

  • Greatly attenuates the effects of low frequency ground loops
  • Supports the 2 Port Shunt Thru impedance measurement required for Power Distribution Networks (PDN’s)
  • Ultra-low noise output - Ultra-high ripple rejection
  • Two output connector versions, BNC and N
  • Maintains 50 Ohm transmission line integrity to at least 6GHz
  • Works with all types of test equipment to eliminate ground loops, such as Network Analyzers, Oscilloscopes and Spectrum Analyzers

2-Port Shunt-Through Measurement using the J2102B and the R&S ZNL

2-Port Shunt-Through Measurement using the J2102B and the R&S ZNL

2-Port Shunt-Through Measurement using the J2102B and the R&S ZNL

2-Port Shunt-Through Measurement using the J2102B and the Copper Mountain S5065

2-Port Shunt-Through Measurement using the J2102B and the Copper Mountain S5065

Detailed Specifications

Specifications
Characteristic Rating
3dB Bandwidth 1Hz-6GHz
Insertion Loss TBD
Return Loss TBD
Maximum Voltage 50V
Temperature Range 0-50C
Maximum Altitude 6000 Ft
Absolute Maximum Voltage < 50VAC and 75VDC