TC.ACS is a series of full digital, full 4 quadrant 3-phase AC power sources with exceptional programming features. Each TC.ACS unit represents a three-in-one configuration:
- Versatile synthesized 3-phase grid simulator with 4 fully controlled active outputs. Operation mode setting per comprehensive software tools. Note the fully active N-connection available at the Simulator Port.
- Built-in full 4-Quadrant 1 to 3-phase power amplifier with outstanding qualities, 3 independent and galvanic isolated amplifier inputs, especially suited for high bandwidth HIL applications within the power laboratory, assisted by an external RT processor.
- Programmable RLC-load mode (electronic AC load with grid recuperation) to substitute real and bulky resistors, inductors and capacitors. Reactive power is recuperated into the 3-phase grid with maximum efficiency.
Applications
By means of the application software ACSControl, the user is enabled to program the following parameters:
- Variation of basic system voltages and frequency
- Settings of phase relationship
- Voltage drops in the whole network or individual drops per phase
- Micro ruptures and flickers
- Over- and under voltages
- Voltage asymmetries
- Superimposed harmonic and interharmonic voltage waveforms
- Variation of phase angles
- Special conditions for EMC testing
- Transition from feeding to recuperation operation and vice versa
- Analyses of energy flow
Hardware
The modular structure based on 30 kVA or 50 kVA units allows for a flexible adaptation to the customer's power requirements. By simply connecting basic units in a parallel mode, systems of up to 1000kVA can be set up. The hardware is operating in all 4 quadrants and is able to fully refeed into the power system. Apart from testing power feedback units, the system also enables the operation of linear and nonlinear feeding systems for measuring and evaluation purposes. An operation in single phase mode is also possible down to DC mode.
User Software ACSControl
The tailor made software tool ACSControl enables the operator either to manually operate the system or to program and run automated test sequences and to use the functionality of data acquisition of the system. Moreover the software offers some screens for parameterising, sequencing, visualising of the current system data and test results as well as for recording and documentation of test results. ACSControl allows also for switching over between the 'Simulator Mode' and the 'Amplifier mode' of the system.
The User's Advantages
The user's advantages are as follows:
- Compact and completely modular design
- High effectivity in all operation modes
- Ability to use an existing liquid cooling system directly
- Optional matched liquid-to-air cooling unit TC.LAE available
- Possibility of upgrading to systems of up to 1 MVA
- High level of system dynamics, ≤ 5 kHz modulation bandwidth
- Non-restrictive capability of refeeding in the Q4 operation mode
- Possibility of operating as an autonomous 4-Q and 3-phase quasi-analogue amplifier
- Possibility of “Hardware-in-the loop”-operation (HIL mode)
- User friendly application software with pre-configured test patterns
- Possibility of integrating into a complete SAS simulation and test system
- Galvanic isolation available as an option without derating the simulator port data
- Three different operation modes:
- Programmable Grid Simulator
- Remote operated 4Q AC voltage amplifier
- Electronic AC-load featuring programmable RLC load impedance
Voltage- / Power- / Current-Range
Voltage Range AC Load Side VAC RMS (L-N) 3L + Active N (4 Outputs) |
Power Range AC Load Side kVA |
Current Range AC Load Side A (Each Phase) |
Order Code | Line Voltage 3L VAC |
Line Frequency Hz |
---|---|---|---|---|---|
0 - 305 V | 30 kVA | 0 - 43 A | ACS.30.528.43 | 360 - 528 V | 48 - 62 Hz |
50 kVA | 0 - 72 A | ACS.50.528.72 | 360 - 528 V | 48 - 62 Hz | |
100 kVA | 0 - 144 A | ACS.100.528.144 | 360 - 528 V | 48 - 62 Hz | |
150 kVA | 0 - 216 A | ACS.150.528.216 | 360 - 528 V | 48 - 62 Hz | |
200 kVA | 0 - 288 A | ACS.200.528.288 | 360 - 528 V | 48 - 62 Hz | |
250 kVA | 0 - 360 A | ACS.250.528.360 | 360 - 528 V | 48 - 62 Hz | |
300 kVA | 0 - 432 A | ACS.300.528.432 | 360 - 528 V | 48 - 62 Hz | |
350 kVA | 0 - 504 A | ACS.350.528.504 | 360 - 528 V | 48 - 62 Hz | |
400 kVA | 0 - 576 A | ACS.400.528.576 | 360 - 528 V | 48 - 62 Hz | |
450 kVA | 0 - 648 A | ACS.450.528.648 | 360 - 528 V | 48 - 62 Hz | |
500 kVA | 0 - 720 A | ACS.500.528.720 | 360 - 528 V | 48 - 62 Hz | |
550 kVA | 0 - 792 A | ACS.550.528.792 | 360 - 528 V | 48 - 62 Hz | |
600 kVA | 0 - 864 A | ACS.600.528.864 | 360 - 528 V | 48 - 62 Hz | |
650 kVA | 0 - 936 A | ACS.650.528.936 | 360 - 528 V | 48 - 62 Hz | |
700 kVA | 0 - 1008 A | ACS.700.528.1008 | 360 - 528 V | 48 - 62 Hz | |
750 kVA | 0 - 1080 A | ACS.750.528.1080 | 360 - 528 V | 48 - 62 Hz | |
800 kVA | 0 - 1152 A | ACS.800.528.1152 | 360 - 528 V | 48 - 62 Hz | |
850 kVA | 0 - 1224 A | ACS.850.528.1224 | 360 - 528 V | 48 - 62 Hz | |
900 kVA | 0 - 1296 A | ACS.900.528.1296 | 360 - 528 V | 48 - 62 Hz | |
950 kVA | 0 - 1368 A | ACS.950.528.1368 | 360 - 528 V | 48 - 62 Hz | |
1000 kVA | 0 - 1440 A | ACS.1000.528.1440 | 360 - 528 V | 48 - 62 Hz | |
≥ 1050 kVA | ≥ 1512 A | Contact Factory | 360 - 528 V | 48 - 62 Hz |
Technical Datasheets
Voltage Range AC Load Side VAC RMS (L-N) 3L + Active N (4 Outputs) |
Power Range AC Load Side kVA |
Current Range AC Load Side A (Each Phase) |
Model Number | Line Voltage 3L VAC |
Line Frequency Hz |
Physical Dimensions W x H x D mm / in |
Weight kg / lbs |
Datasheet |
---|---|---|---|---|---|---|---|---|
0 - 305 V | 30 kVA | 0 - 43 A | TC.ACS.30.528.4WR.S.LC | 360 - 528 V | 48 - 62 Hz | 19" x 11U x 634 mm / 25" | 150 kg / 330 lbs | PDF (517KB) |
50 kVA | 0 - 72 A | TC.ACS.50.528.4WR.S.LC | 360 - 528 V | 48 - 62 Hz | 19" x 11U x 634 mm / 25" | 150 kg / 330 lbs | PDF (517KB) |
Options and Accessories
Option Code | Short description of option / accessory | ||
---|---|---|---|
Multi-Unit Operation | |||
ACSCommcable | Connecting Cables for Multi-Unit Operation; specify length 2m, 5m, 10m | ||
Control Interfaces | |||
TC.ACS.DIG8IOST | Digital I/O Interface for TC.ACS | PDF (440KB) | |
X609 Adapter | M12 circular connector to 4x BNC (Analogue out) and 8x screw terminals (Analogue in / supply); includes data cable and box | ||
TC.ACSUSense | Senseboard TC.ACS | PDF (440KB) | |
Application Software | |||
GridSim | Grid Simulation Software (for Development and Process Automation) | ||
RLC-Load Mode | AC Load Simulation | ||
Current Control Mode | Additional current controlled mode for ACS | ||
Environmental Conditions | |||
LAE.5.400 | "Liquid => Air" Heat Exchanger Unit, 19-Inch Rack-Mount, 4HU; 5kW cooling capacity, supply voltage 380-480VAC wide range | PDF (398KB) | |
LAE.5.230 | Liquid => Air" Heat Exchanger Unit, 19-Inch Rack-Mount, 4HU; 5kW cooling capacity, supply voltage 100-240VAC wide range | PDF (398KB) | |
Output Range Modifications | |||
NSOV AC | Non-Standard AC Voltage; contact factory for feasibility | ||
NSOC AC | Non-Standard AC Current; contact factory for feasibility | ||
Input Range Modifications | |||
NSIV | Non-Standard AC Voltage; contact factory for feasibility | ||
Miscellaneous | |||
TC.ADI | Filter, AC Decoupling Inductors, 19-Inch Rack-Mount Unit, 4HU | ||
Service | |||
Calib.Protocol | Calibration Protocol | ||
Warranty +1J | Warranty extension +1 year | ||
Warranty +2J | Warranty extension +2 years |