MASTER/ SLAVE INTERFACE SM15K Print this pagePrint this page
MASTER/ SLAVE INTERFACE SM15K
Price:

Highlights:
  • Interface for master/slave series or parallel operation of SM15K power supply units.
  • Plug and Play module

Description

Master/Slave interface SM15K

Product Details

Features

  • For applications where more current is required than 1 SM15K unit can deliver
  • Optimal dynamic response in parallel operation
  • Fast reaction time: up to 250 uSec

Functionalities

  • Multiple power supplies behave as one large system
  • All information visible on master
  • For SM15K series only and max. 1 pc INT MOD M/S 2 per unit possible
  • Master/Slave parallel operation SM500-CP-90, SM1500-CP-30: up to 60 units (identical)
  • Max. 6 units SM70-CP-450 in parallel operation
  • Max. 6 units SM500-CP-90 in series operation
  • Series operation not possible for SM70-CP-450 and SM1500-CP-30
  • Installation in slot 3 or 4 only (rear end of power supply)
  • Easy to plug in or remove by user at site

Options

  • Master/Slave assembly kit SM15K

    Connection sets for Master/Slave set-ups using the M/S PAR and the M/S SER assembly kits.

     

    SM70-CP-450

      • M/S PAR SET A2 — for 2 units in parallel
      • M/S PAR SET A3 — for 3 units in parallel
      • M/S PAR SET A4 — for 4 units in parallel
      • M/S PAR SET A5 — for 5 units in parallel
      • M/S PAR SET A6 — for 6 units in parallel
     

    SM210-CP-150, SM500-CP-90 and SM1500-CP-30

      • M/S PAR SET C2 — for 2 units in parallel
      • M/S PAR SET C3 — for 3 units in parallel
      • M/S PAR SET C4 — for 4 units in parallel
      • M/S PAR SET C5 — for 5 units in parallel
      • M/S PAR SET C6 — for 6 units in parallel
      • M/S PAR SET C7 — for 7 units in parallel
      • M/S PAR SET C8 — for 8 units in parallel
      • M/S PAR SET C9 — for 9 units in parallel
      • M/S PAR SET C10 — for 10 units in parallel
      • M/S PAR SET C11 — for 11 units in parallel
      • M/S PAR SET C12 — for 12 units in parallel
      • 13 to 20 in parallel  — see application note
      • 21 to 60 in parallel — contact factory
     
    SM500-CP-90
      • M/S SER SET BA — for 2 units in series
      • M/S SER SET BB — for 3 to 6 units in series

 

 Data sheet        Product manual


Specification
Specifications
Operating temperature -20 to +50 ēC
Standards
Safety EN 60950 / EN 61010
Dimensions and weight
Width 25 mm
Height 77 mm
Depth 77 mm
Weight 70 gr