Home Page
Home|Sitemap|Contact
Singapore - 
	DT TECHSOLUTIONS PTE LTD   India - DT TECHSOLUTIONS PVT LTD
Home Page
Your Cart
Your shopping cart is empty!

Currency
American Dollar

Automotive Test Scope ATS605004D-XMS

Printer Friendly Tell a Friend
Automotive Test Scope ATS605004D-XMS
Price: USD1,993.20

Qty:

Highlights:
  • 14 bit (0.006 %) resolution (16 bit enhanced resolution)
  • Up to 500 MSa/s sampling
  • 250 MHz bandwidth

  Description  

Automotive Test Scope ATS605004D-XMS

Product Details

Key specifications

  • 14 bit (0.006 %) resolution (16 bit enhanced resolution)
  • Up to 500 MSa/s sampling
  • 250 MHz bandwidth
  • Up to 100 MSa/s continuous streaming
  • Up to 256 Mpoints memory per channel
  • 0.25 % DC vertical accuracy, 0.1 % typical
  • 1 ppm time base accuracy

This powerful USB 3.0 super speed automotive oscilloscope combines fast sampling up to 500 MSa/s with high resolutions of 12, 14 and 16 bit and a large memory of 64 Mpoints on all four channels. Additionally, the automotive oscilloscope supports continuous streaming measurements up to 100 MSa/s.

The Automotive Test Scope ATS605004D-XMS is delivered with SureConnect connection test and resistance measurement on each channel.

Specifications

Acquisition system

Number of input channels4 analog
CH1, CH2, CH3, CH4Isolated BNC, female
TypeDifferential input
ResolutionUser selectable in software
Native8, 12, 14 bit
Enhanced16 bit
DC Accuracy0.25 % (0.1 % typical) of full scale ± 1 LSB at 20°C to 25°C
To achieve rated accuracy, allow the instrument to settle for 20 minutes. When subjected to extreme temperatures, allow additional time for internal temperatures to stabilize.
Noise305 µVrms (200 mV range, 12 bit, 50 MSa/s)
90 µVrms (200 mV range, 16 bit, 6.25 MSa/s)
Ranges±200 mV
±400 mV
±800 mV
±2 V
±4 V
±8 V
±20 V
±40 V
±80 V
CouplingAC/DC
Impedance2 MOhm / 12 pF ± 1 %
Maximum voltage200 V (DC + AC peak < 10 kHz)
Maximum Common Mode voltage200 mV to 800 mV ranges 2 V
2 V to 8 V ranges : 20 V
20 V to 80 V ranges : 200 V
Common Mode Rejection Ratio-47 dB
Bandwidth 
-3dB at 75 % of full scale input250 MHz
Limit, selectable per channelOff (250 MHz), 150 MHz, 100 MHz, 50 MHz
AC coupling cut off frequency (-3dB)±1.5 Hz
SureConnect 
Maximum voltage on connection200 V (DC + AC peak < 10 kHz)
Resistance measurement 
Ranges100 Ω
200 Ω
500 Ω
1 kΩ
2 kΩ
5 kΩ
10 kΩ
20 kΩ
50 kΩ
100 kΩ
200 kΩ
500 kΩ
1 MΩ
2 MΩ
Accuracy1 % of full scale
Response time (to 95%)< 10 µs
 
Maximum sampling rate8 bit12 bit14 bit16 bit
measuring one channel500 MSa/s200 MSa/s50 MSa/s3.125 MSa/s
measuring two channels200 MSa/s100 MSa/s50 MSa/s3.125 MSa/s
measuring three or four channels100 MSa/s50 MSa/s50 MSa/s3.125 MSa/s
 
Maximum streaming rate 18 bit12 bit14 bit16 bit 
measuring one channel100 MSa/s250 MSa/s350 MSa/s33.125 MSa/s
measuring two channels50 MSa/s325 MSa/s425 MSa/s43.125 MSa/s
measuring three or four channels20 MSa/s412.5 MSa/s512.5 MSa/s53.125 MSa/s
  1. On some computers, the highest streaming rates may not be available, due to computer restrictions.
  2. ≤ 40 MSa/s when connected to USB 2.0
  3. ≤ 20 MSa/s when connected to USB 2.0
  4. ≤ 10 MSa/s when connected to USB 2.0
  5. ≤ 5 MSa/s when connected to USB 2.0
Sampling clock source 
InternalTCXO
Accuracy± 0.0001 %
Stability± 1 ppm over 0°C to 55°C
Time base aging±1 ppm/year
ExternalLVDS, on CMI connectors
Input range10 MHz ± 1 %
16.369 MHz ± 1 %
 
Memory8 bit12, 14, 16 bit
Measuring one channel256 Mpoints per channel128 Mpoints per channel
Measuring two channels128 Mpoints per channel64 Mpoints per channel
Measuring three or four channels64 Mpoints per channel32 Mpoints per channel
 
Trigger Only available in scope/block mode, not in streaming mode
SystemDigital, 2 levels
SourceCH1, CH2, CH3, CH4, OR, digital external
Trigger modesRising edge, Falling edge, Any edge
Inside window, Outside window, Enter window, Exit window (time conditions only on Ch1)
Pulse width (only on Ch1)
Interval (only on Ch1)
Level adjustment0 to 100 % of full scale
Hysteresis adjustment0 to 100 % of full scale
Resolution0.006 % (14, 16 bits) / 0.025% (12 bits)
Pre trigger0 to selected record length, 1 sample resolution
Post trigger0 to selected record length, 1 sample resolution
Trigger hold-off0 to 63 MSamples, 1 sample resolution
Trigger delay0 to 8 GSamples, 1 sample resolution
Digital external trigger 
InputExtension connector pins 1 and 2
Range0 to 2.5 V (TTL)
CouplingDC
Jitter≤ 1 sample

Multi-instrument synchronization

Using CMISynchronizing instruments via CMI is available when all instruments are connected via USB.
Maximum number of instrumentsLimited by number of available USB ports
Synchronization accuracy0 ppm
CMI interface2x, CMI 1, CMI 2
Required coupling cableTP-C50H Coupling cable CMI
Maximum coupling cable length50 cm
Using WCMISynchronizing instruments via WCMI is available when instruments are connected via USB, LAN and WiFi.
Maximum number of instrumentsNo limitation
Required coupling moduleWCMI - 8, WCMI - 9
Clock synchronization accuracy≤ 1 ppm, typical ≤ 0.2 ppm
Trigger jitter at sample rate 1≤ 1 MSa/s> 1 MSa/s
2 x "5"≤ ±2 samples≤ ±2 µs
"5" and "6" 
Trigger source "5"≤ ±2 samples≤ ±2 µs
Trigger source "6"≤ ±8 samples≤ ±8 µs
2 x "6"≤ ±8 samples≤ ±8 µs
  1. "5" = WiFiScope WS5 or Handyscope HS5.
    "6" = WiFiScope WS6 DIFF, WiFiScope WS6, Handyscope HS6 DIFF, Handyscope HS6, ATS610004DW-XMSG, ATS610004D-XMSG, ATS605004DW-XMS or ATS605004D-XMS

Probe calibration

OutputExtension connector pins 3 (signal) and 6 (ground)
SignalSquare wave
Level-1 V to 1 V
Frequency1 kHz

Interface

InterfaceUSB 3.0 SuperSpeed (5 Gbit/s);
(USB 2.0 HighSpeed compatible)

Power Requirements

PowerFrom USB port or external input
Consumption5 VDC 1200 mA max
External powerFrom second USB port or power adapter

Physical

Instrument
Height25 mm (1 inch)
Length170 mm (6.7 inch)
Width140 mm (5.2 inch)
Weight500 g (17.6 ounce)
USB cord length1.8 m (70 inch)

I/O connectors

Channel 1, 2, 3, 4Isolated BNC, female
USBFixed cable with USB 3.0 type A connector, 1.8 m
Extension connectorD-sub 9 pins female
Power3.5 mm power socket
CMI I/O connectors2 x HDMI type C socket

System requirements

PC I/O connectionUSB 2.0, USB 3.0 or USB 3.1
Operating systemWindows 10 / 11, 64 bits
Linux (via libtiepie-hw SDK)

Environmental conditions

Operating 
Ambient temperature20°C to 25°C (10°C to 40°C without specifications)
Relative humidity10 % to 90 %, non condensing
Storage 
Ambient temperature-20°C to 70°C
Relative humidity5 % to 95 %, non condensing

Certifications and Compliances

CE mark complianceYes
RoHSYes
EN 55011:2009/A1:2010Yes
EN 55022:2006/A1:2007Yes
EN 61000-6-1:2007Yes
EN 61000-6-3:2007Yes

Package contents

InstrumentAutomotive Test Scope ATS605004D-XMS
Measure leads4 x Measure lead TP-C1812B, Differential BNC -> 4 mm banana plug
Differential attenuator4 x Differential attenuator TP-DA10
AccessoriesHandyscope power supply, external power cable for USB port
Softwarefor Windows 10 / 11, 64 bits, via website
Driversfor Windows 10 / 11, 64 bits, via website
Manualsinstrument manual and software user's manuals
color printed and digital, via website

Customer service

TiePie engineering instruments are designed, manufactured and tested to provide high reliability. In the unlikely event you experience difficulties, the TiePie engineering instruments are fully warranted for two years.
This warranty includesAll parts and labor (excluding measure leads/probes)
No charge for return shipping
Long-term 7 year support
Upgrade to the latest software at no charge

 User Manual

© 2013 DT TECHSOLUTIONS PTE LTD