Key specifications
- 14 bit (0.006 %) resolution (16 bit enhanced resolution)
- Up to 500 MSa/s sampling
- 250 MHz bandwidth
- Up to 100 MSa/s continuous streaming
- Up to 256 Mpoints memory per channel
- 0.25 % DC vertical accuracy, 0.1 % typical
- 1 ppm time base accuracy
This powerful USB 3.0 super speed automotive oscilloscope combines fast sampling up to 500 MSa/s with high resolutions of 12, 14 and 16 bit and a large memory of 64 Mpoints on all four channels. Additionally, the automotive oscilloscope supports continuous streaming measurements up to 100 MSa/s.
![]() |
![]() |
![]() |
![]() |
![]() |
The Automotive Test Scope ATS605004D-XMS is delivered with SureConnect connection test and resistance measurement on each channel.
Specifications
Acquisition system | |||||
---|---|---|---|---|---|
Number of input channels | 4 analog | ||||
CH1, CH2, CH3, CH4 | Isolated BNC, female | ||||
Type | Differential input | ||||
Resolution | User selectable in software | ||||
Native | 8, 12, 14 bit | ||||
Enhanced | 16 bit | ||||
DC Accuracy | 0.25 % (0.1 % typical) of full scale ± 1 LSB at 20°C to 25°C To achieve rated accuracy, allow the instrument to settle for 20 minutes. When subjected to extreme temperatures, allow additional time for internal temperatures to stabilize. | ||||
Noise | 305 µVrms (200 mV range, 12 bit, 50 MSa/s) 90 µVrms (200 mV range, 16 bit, 6.25 MSa/s) | ||||
Ranges | ±200 mV ±400 mV ±800 mV | ±2 V ±4 V ±8 V | ±20 V ±40 V ±80 V | ||
Coupling | AC/DC | ||||
Impedance | 2 MOhm / 12 pF ± 1 % | ||||
Maximum voltage | 200 V (DC + AC peak < 10 kHz) | ||||
Maximum Common Mode voltage | 200 mV to 800 mV ranges 2 V 2 V to 8 V ranges : 20 V 20 V to 80 V ranges : 200 V | ||||
Common Mode Rejection Ratio | -47 dB | ||||
Bandwidth | |||||
-3dB at 75 % of full scale input | 250 MHz | ||||
Limit, selectable per channel | Off (250 MHz), 150 MHz, 100 MHz, 50 MHz | ||||
AC coupling cut off frequency (-3dB) | ±1.5 Hz | ||||
SureConnect | |||||
Maximum voltage on connection | 200 V (DC + AC peak < 10 kHz) | ||||
Resistance measurement | |||||
Ranges | 100 Ω 200 Ω 500 Ω | 1 kΩ 2 kΩ 5 kΩ | 10 kΩ 20 kΩ 50 kΩ | 100 kΩ 200 kΩ 500 kΩ | 1 MΩ 2 MΩ |
Accuracy | 1 % of full scale | ||||
Response time (to 95%) | < 10 µs | ||||
Maximum sampling rate | 8 bit | 12 bit | 14 bit | 16 bit | |
measuring one channel | 500 MSa/s | 200 MSa/s | 50 MSa/s | 3.125 MSa/s | |
measuring two channels | 200 MSa/s | 100 MSa/s | 50 MSa/s | 3.125 MSa/s | |
measuring three or four channels | 100 MSa/s | 50 MSa/s | 50 MSa/s | 3.125 MSa/s | |
Maximum streaming rate 1 | 8 bit | 12 bit | 14 bit | 16 bit | |
measuring one channel | 100 MSa/s2 | 50 MSa/s3 | 50 MSa/s3 | 3.125 MSa/s | |
measuring two channels | 50 MSa/s3 | 25 MSa/s4 | 25 MSa/s4 | 3.125 MSa/s | |
measuring three or four channels | 20 MSa/s4 | 12.5 MSa/s5 | 12.5 MSa/s5 | 3.125 MSa/s | |
Sampling clock source | |||||
Internal | TCXO | ||||
Accuracy | ± 0.0001 % | ||||
Stability | ± 1 ppm over 0°C to 55°C | ||||
Time base aging | ±1 ppm/year | ||||
External | LVDS, on CMI connectors | ||||
Input range | 10 MHz ± 1 % 16.369 MHz ± 1 % | ||||
Memory | 8 bit | 12, 14, 16 bit | |||
Measuring one channel | 256 Mpoints per channel | 128 Mpoints per channel | |||
Measuring two channels | 128 Mpoints per channel | 64 Mpoints per channel | |||
Measuring three or four channels | 64 Mpoints per channel | 32 Mpoints per channel | |||
Trigger | Only available in scope/block mode, not in streaming mode | ||||
System | Digital, 2 levels | ||||
Source | CH1, CH2, CH3, CH4, OR, digital external | ||||
Trigger modes | Rising edge, Falling edge, Any edge Inside window, Outside window, Enter window, Exit window (time conditions only on Ch1) Pulse width (only on Ch1) Interval (only on Ch1) | ||||
Level adjustment | 0 to 100 % of full scale | ||||
Hysteresis adjustment | 0 to 100 % of full scale | ||||
Resolution | 0.006 % (14, 16 bits) / 0.025% (12 bits) | ||||
Pre trigger | 0 to selected record length, 1 sample resolution | ||||
Post trigger | 0 to selected record length, 1 sample resolution | ||||
Trigger hold-off | 0 to 63 MSamples, 1 sample resolution | ||||
Trigger delay | 0 to 8 GSamples, 1 sample resolution | ||||
Digital external trigger | |||||
Input | Extension connector pins 1 and 2 | ||||
Range | 0 to 2.5 V (TTL) | ||||
Coupling | DC | ||||
Jitter | ≤ 1 sample | ||||
Multi-instrument synchronization | |||||
Using CMI | Synchronizing instruments via CMI is available when all instruments are connected via USB. | ||||
Maximum number of instruments | Limited by number of available USB ports | ||||
Synchronization accuracy | 0 ppm | ||||
CMI interface | 2x, CMI 1, CMI 2 | ||||
Required coupling cable | TP-C50H Coupling cable CMI | ||||
Maximum coupling cable length | 50 cm | ||||
Using WCMI | Synchronizing instruments via WCMI is available when instruments are connected via USB, LAN and WiFi. | ||||
Maximum number of instruments | No limitation | ||||
Required coupling module | WCMI - 8, WCMI - 9 | ||||
Clock synchronization accuracy | ≤ 1 ppm, typical ≤ 0.2 ppm | ||||
Trigger jitter at sample rate 1 | ≤ 1 MSa/s | > 1 MSa/s | |||
2 x "5" | ≤ ±2 samples | ≤ ±2 µs | |||
"5" and "6" | |||||
Trigger source "5" | ≤ ±2 samples | ≤ ±2 µs | |||
Trigger source "6" | ≤ ±8 samples | ≤ ±8 µs | |||
2 x "6" | ≤ ±8 samples | ≤ ±8 µs | |||
Probe calibration | |||||
Output | Extension connector pins 3 (signal) and 6 (ground) | ||||
Signal | Square wave | ||||
Level | -1 V to 1 V | ||||
Frequency | 1 kHz | ||||
Interface | |||||
Interface | USB 3.0 SuperSpeed (5 Gbit/s); (USB 2.0 HighSpeed compatible) | ||||
Power Requirements | |||||
Power | From USB port or external input | ||||
Consumption | 5 VDC 1200 mA max | ||||
External power | From second USB port or power adapter | ||||
Physical | |||||
Instrument | |||||
Height | 25 mm (1 inch) | ||||
Length | 170 mm (6.7 inch) | ||||
Width | 140 mm (5.2 inch) | ||||
Weight | 500 g (17.6 ounce) | ||||
USB cord length | 1.8 m (70 inch) | ||||
I/O connectors | |||||
Channel 1, 2, 3, 4 | Isolated BNC, female | ||||
USB | Fixed cable with USB 3.0 type A connector, 1.8 m | ||||
Extension connector | D-sub 9 pins female | ||||
Power | 3.5 mm power socket | ||||
CMI I/O connectors | 2 x HDMI type C socket | ||||
System requirements | |||||
PC I/O connection | USB 2.0, USB 3.0 or USB 3.1 | ||||
Operating system | Windows 10 / 11, 64 bits Linux (via libtiepie-hw SDK) | ||||
Environmental conditions | |||||
Operating | |||||
Ambient temperature | 20°C to 25°C (10°C to 40°C without specifications) | ||||
Relative humidity | 10 % to 90 %, non condensing | ||||
Storage | |||||
Ambient temperature | -20°C to 70°C | ||||
Relative humidity | 5 % to 95 %, non condensing | ||||
Certifications and Compliances | |||||
CE mark compliance | Yes | ||||
RoHS | Yes | ||||
EN 55011:2009/A1:2010 | Yes | ||||
EN 55022:2006/A1:2007 | Yes | ||||
EN 61000-6-1:2007 | Yes | ||||
EN 61000-6-3:2007 | Yes | ||||
Package contents | |||||
Instrument | Automotive Test Scope ATS605004D-XMS | ||||
Measure leads | 4 x Measure lead TP-C1812B, Differential BNC -> 4 mm banana plug | ||||
Differential attenuator | 4 x Differential attenuator TP-DA10 | ||||
Accessories | Handyscope power supply, external power cable for USB port | ||||
Software | for Windows 10 / 11, 64 bits, via website | ||||
Drivers | for Windows 10 / 11, 64 bits, via website | ||||
Manuals | instrument manual and software user's manuals color printed and digital, via website | ||||
Customer service | |||||
TiePie engineering instruments are designed, manufactured and tested to provide high reliability. In the unlikely event you experience difficulties, the TiePie engineering instruments are fully warranted for two years. | |||||
This warranty includes | All parts and labor (excluding measure leads/probes) No charge for return shipping Long-term 7 year support Upgrade to the latest software at no charge |